Brands that use this code
A.O. Smith owns State (announced 2001), American Water Heater (2006) and Lochinvar (2011). CPSC’s 2018 recall notice applies the same year-and-week rule to heaters sold as American, A.O. Smith, Kenmore, Reliance, State, U.S. Craftmaster and Whirlpool. Kenmore and Whirlpool water heaters have had other makers over the years, so check the maker’s name in the small print on the plate. American and Whirlpool and Kenmore heaters are covered below; see also Reliance. Lochinvar tanks use their own code: see Lochinvar water heater age.
Basis: official (CPSC recall 19-029); ownership dates from A.O. Smith releases as reported by Building Intelligence Center.
Where the serial number is
| Model | Where to look |
|---|---|
| A.O. Smith gas | On the data plate next to the gas control valve/thermostat |
| A.O. Smith sold at Lowe’s | Possibly on the label near the bottom of the heater |
| State | On the nameplate on the side of the unit |
Basis: official (CPSC recall 19-029; A.O. Smith at Lowe’s owner center; State Water Heaters).
Serials from about 2008 on: year and week
CPSC’s 2018 A.O. Smith recall notice: “the first four digits represent the year and week of production.”
| Serial starts | Year | Week | Built |
|---|---|---|---|
| 1210A002243 | 2012 | 10 | early March 2012 |
| 0833A032628 | 2008 | 33 | mid-August 2008 |
| 1836111786352 | 2018 | 36 | early September 2018 |
| 1805 to 1809 | 2018 | 5–9 | about February 2018 (CPSC 19-030 range) |
Basis: official (CPSC 19-029 and 19-030, both US recall notices). A.O. Smith’s European site describes the same rule for its European products (2037 = week 37 of 2020); we use it only as supporting evidence. Examples: Building Intelligence Center and a Reliance/State serial posted on the InterNACHI forum.
If a letter comes first (for example S1318F000046), skip it and read the first four digits: 2013, week 18.
Older serials: month letter and year
| Letter | Month | Letter | Month |
|---|---|---|---|
| A | January | G | July |
| B | February | H | August |
| C | March | J | September |
| D | April | K | October |
| E | May | L | November |
| F | June | M | December |
There’s no I. Basis: official (CPSC recall 06-002, which lists “Jan-04 - MA04 or AA04 or A04” through “Jul-05 – G05”).
Which letter to read depends on the layout:
| Layout | Read | Example | Built |
|---|---|---|---|
| Letter + 2 digits (A.O. Smith from about July 2004; State for longer; used until about 2008–2010) | 1st letter = month, digits = year | L07A071460 | November 2007 |
| 2 letters + 2 digits (A.O. Smith before about July 2004) | 1st letter = a code (not the date), 2nd = month, digits = year | MD91… | April 1991 |
Basis: official (CPSC 08-241 lists L07A and M07A serials for heaters sold November 2007 to January 2008; CPSC 06-002 shows the switch to single-letter codes from July 2004; CPSC’s 1991 notice covers serials beginning MD91 to MG91, made April 16 to July 9, 1991).
A correction to one popular chart: InterNACHI’s dating chart gives J as October. CPSC’s official serial table (J04 = September 2004) shows J is September; our table follows CPSC.
American Water Heater units used year + week even before A.O. Smith bought the company in 2006 (InterNACHI’s chart: “8906xxx= made in the 6th week of the year 1989”). More: American water heaters below.
Recalls to know about
These CPSC recalls name A.O. Smith or State heaters. Most used the serial date code to define which heaters were affected:
| Recall | What | How to tell (serials or codes covered) |
|---|---|---|
| CPSC 19-029 (Nov 2018) | Ultra-Low NOx gas water heaters: fire hazard | First four digits 1115 to 1631 (made April 2011 to August 2016) |
| CPSC 19-030 | 30-gallon gas water heaters sold only at Lowe’s: fire hazard | First four digits 1805 to 1809 |
| CPSC 15-155 (Jun 2015) | John Wood brand 50- and 70-gallon oil-fired water heaters, recalled by A.O. Smith: “The water heater’s combustion chamber can be misaligned and heat the exterior walls of the water heater instead of the water.” Fire and burn hazards. About 250 units | JW517: serials 1349A021678 through 1503A016643. JW717: serials 1421M001517 through 436M000040 (as printed by CPSC) |
| CPSC 08-241 (Apr 2008) | 75-gallon natural and propane gas water heaters with “A.O. Smith” or “State” on the side, sold November 2007 to January 2008: flue gas can get too hot and exhaust can leak into the room, fire and carbon monoxide hazards. About 1,500 units | A.O. Smith FCG-75 300 and FCG-75 301; State GS6 75 XRR S and GS6 75 CRR S; serials L07A071460 to L07A144966 or M07A009387 to M07A072884 |
| CPSC 06-002 (Oct 2005) | 75-gallon propane gas water heaters with “A.O. Smith,” “Reliance,” “Apollo,” “State,” or “Maytag” on the side: “The water heaters can accumulate soot on the burners, posing a fire hazard.” About 5,000 units | A.O. Smith models BT-80-271, FCG-75-271, PCG-75-271; State models GS675CRRS, GS675CRRSD, SBS7576PE, SBS7576PED, SBS7576PECGA, SBS7576PECGAD (other brands’ models on the notice). Made January 2004 to July 2005: serials beginning MA04, AA04 or A04 (January 2004) through G05 (July 2005) |
| CPSC 04-128 (Apr 2004) | White-Rodgers LP and convertible gas water heater controls on several brands, including AO Smith, Reliance and State: soot can build up on the burner, a fire hazard. 88,000 units | Date codes 0240 to 0329, a four-digit code stamped on the control (not the heater serial) |
| CPSC 92-016 (Nov 1991) | A.O. Smith FSG and PGX 30- and 40-gallon natural and LP gas water heaters: oversized flue baffles “may produce unacceptably high levels of carbon monoxide” | Serials beginning MD91, ME91, MF91 or MG91 (made April 16 to July 9, 1991) |
| CPSC 80-042 (Dec 1980) | LP gas water heaters with White-Rodgers thermostats from several makers, sold between 1961 and 1980, including A.O. Smith brand names (such as A.O. Smith, Glascote, Permaglas and Signet) and State Industries brand names (such as Sentry, President and Censible): the thermostat’s safety valve could stick open and let LP gas escape, an explosion hazard. About 600,000 units, all makers | An LP gas heater sold under a name on the notice between 1961 and 1980 |
Basis: official (CPSC notices in the sources). Old recalls may have closed, and the phone numbers and web addresses in them may no longer work. Always check the exact model on the notice, and run the model through our recall check.
Boilers too. Two Lochinvar recalls also cover A.O. Smith- and State-brand condensing boilers, combi boilers and packaged systems, which can emit carbon monoxide: CPSC 20-141 (June 2020; sold after August 2016, serials 103475818 to 115078306) and CPSC 24-018 (November 2023; A.O. Smith models starting ACB, State Industries models starting SCB, serials 125325485 to 134830284). Details: Lochinvar recalls.
If you can’t read it
Many newer plates print the date. Otherwise, contact A.O. Smith or State technical support (877-552-0010) with the model and serial number.
What the age means
A.O. Smith says traditional tank water heaters last 8 to 12 years and tankless models 15 to 20. Across published sources a tank typically lasts about 11 years (range 8 to 15); see how long water heaters last.
Comparing quotes? See what a new water heater costs installed. For the heating and cooling side of the house, the furnace or air conditioner’s serial carries a date too: Goodman, Carrier and Bryant, Trane and American Standard.
Limitations
- We couldn’t find the exact date A.O. Smith and State switched to the year-and-week code. The latest letter-coded units in CPSC records were sold into January 2008, the earliest year-and-week serial we found is from week 33 of 2008, and Building Intelligence Center says one letter style was discontinued “somewhere between 2008-2010”. The checker reads a month letter with a year up to 2010 as the older code.
- Week numbers give the week, not the day; we show the month that week falls in.
- A.O. Smith’s own published statement of the week rule is on its European site. For US models our official source is CPSC’s notice covering 2011–2016 production, and the 2018 serials in CPSC 19-030 fit the same code; we found no US A.O. Smith page that states it.
American water heaters
American Water Heater Company built its heaters in Johnson City, Tennessee (New York City equipment approval 87-88-E). A.O. Smith bought American’s parent company, GSW, in April 2006; its release says American “markets residential and commercial water heaters under the American PROLine ® and U. S. Craftsmaster ® brands” [sic: most CPSC notices spell it Craftmaster]. American’s support page now gives an Ashland City, Tennessee address. American also built the Whirlpool-brand water heaters sold at Lowe’s: see Whirlpool and Kenmore water heaters below.
Basis: official (A.O. Smith release; NYC Department of Buildings; americanwaterheater.com).
Don’t confuse it with American Appliance Manufacturing. Inspectapedia: “These are two different companies with very similar names,” and their serial codes differ.
Reading an American serial
American’s tanks use the year-and-week code above, and used it long before the A.O. Smith purchase. American’s warranty gives the rule by example: “Serial No. 9843113460 Tank was manufactured 43rd week of 1998.” Digits 3 and 4 are the week, not the month: a value like 43 can’t be a month. CPSC’s 2001 American recall puts the serial “on the data plate on the front of the water heater”; look there, and don’t remove any covers or access panels to find it.
| Serial | Year | Week | Built | Where the example comes from |
|---|---|---|---|---|
| 9843113460 | 1998 | 43 | late October 1998 | American Water Heater warranty (stated) |
| 9950123040 | 1999 | 50 | mid-December 1999 | Inspectapedia (stated) |
| 1924115263020 | 2019 | 24 | mid-June 2019 | Building Intelligence Center (our reading of its rule) |
| 0124 to 0127 | 2001 | 24 to 27 | mid-June to early July 2001 | CPSC 02-020 serial range (our reading; the heaters were sold June to September 2001) |
Basis: official (American Water Heater warranty, 2022; CPSC recall 19-029). The 02-020 row is our reading of CPSC’s serial range. Inspectapedia and InterNACHI’s dating chart give the same rule. The rest of the serial is a production number and can include a letter. Two-digit years repeat every century; a heater still in use reading 98 is from 1998.
One reference reads it differently. Building Intelligence Center labels one American style as year and month. American’s own warranty and CPSC read the same position as the week, and we follow them.
Tankless models. American’s tankless heaters have their own support lines, and we found no documented serial format for them. Don’t read a tankless serial with the year-and-week rule; call American (gas tankless 877-566-4549, electric tankless 877-553-7659). Heat pump models aren’t covered here either.
If you can’t read it. American tank questions go to the same 877-552-0010 support number given above; American lists its hours as weekdays 8 am to 10 pm and weekends 9 am to 6 pm, Eastern time. A warranty verification form on American’s website also takes a serial number. We haven’t tried that form, so whether it returns a build date is unknown to us.
Warranty and lifespan. American doesn’t publish a lifespan figure. It says “How long your water heater lasts depends on how often you use it, your groundwater quality, and how regularly you maintain it,” and that its gas tank warranties range from 6 to 10 years.
American recalls
CPSC 19-029, in the table above, also covers American-brand heaters: about 616,000 Ultra-Low NOx 30-, 40- and 50-gallon gas heaters sold under seven brands, mainly in California, whose burner screen can tear, a fire hazard on combustible floors. American’s line for it: 866-854-2793. These older notices name American brands:
| Recall | What | How to tell |
|---|---|---|
| CPSC 05-274 (Sep 2005) | Robertshaw R110 gas control valves on natural gas and LP heaters of several brands, including American Proline, Premier Plus, Powerflex and U.S. Craftmaster: “gas could leak from the valve, which poses a risk of gas explosion and fire.” About 178,000 units, all brands | Valves made July 25 to August 14, 2005, with production date codes 5-31 through 5-33, “although not all valves with these date codes are affected.” Electric heaters aren’t included |
| CPSC 02-020 (Oct 2001) | Natural gas heaters sold as American Proline, Envirotemp, Mor-Flo, Powerflex, Premier Plus and US Craftmaster: “The burners could produce excess carbon monoxide (CO).” About 16,000 units | Serial starts 0124 to 0127 |
| CPSC 96-191 (Sep 1996) | LP Polaris Comfort Systems combination water and home heaters sold 1985 to July 1996: “fuel gas may ignite explosively, causing property damage or injury.” About 6,500 units | Models PR34LPGV, PR50LPGV, PR34LPGFV, PR50LPGFV, PC100-34LPGV, PC100-50LPGV, PBG102-34S100-2P, PBG102-50T100-2P, PBCG32-34S100-2P, PBCG32-50S100-2P, PBCG52-34S100-2P, PBCG52-50S100-2P, DVPB35LPGV and PVG-34S100-2P, on the data plate on the front of the heater about three feet above the floor |
Basis: official (CPSC notices in the sources). Old recalls may have closed; check the notice for the exact models, and run the model through our recall check.
A different brand: CPSC 16-171 (May 2016) recalled “American Standard” gas water heaters (models beginning GN and GSN) from Water Heating Technologies Corp. The notice doesn’t name American Water Heater Company, so it isn’t listed above; if your heater has an “American Standard” logo, check that notice.
Whirlpool and Kenmore water heaters
Neither Whirlpool nor Sears built the water heaters sold under their names. Most of them came from companies that A.O. Smith owns today, so they carry the codes above, but the maker named in the small print on the plate decides which code applies.
Who built Whirlpool’s heaters
In October 2000, American Water Heater Company announced a license to supply Whirlpool-brand water heaters to Lowe’s. When A.O. Smith bought American’s parent, GSW, in April 2006, its release called American “the exclusive supplier of water heaters to Lowe’s, supplying residential gas and electric units carrying the Whirlpool® brand.”
Whirlpool’s own site now says: “Whirlpool® Water Heaters are no longer available.” A.O. Smith’s report for 2018 describes “a long-standing exclusive relationship with Lowe’s where we sell A. O. Smith branded products.” We couldn’t find when the Whirlpool brand ended.
Basis: official (A.O. Smith’s 2006 acquisition release and 2018 annual report, whirlpool.com) and trade press (Plumbing & Mechanical, 2000).
Don’t use the Whirlpool appliance code. Whirlpool washers, dryers and fridges read the year from a letter. That rule doesn’t apply to water heaters, although some pages that rank for “Whirlpool water heater age” use it.
Reading a Whirlpool serial
Whirlpool’s water heater site says “the serial number may be found on the label near the bottom of the water heater.” That label is the rating plate, and the model number is printed on it too.
Read the first four digits with the year-and-week code: digits 1 and 2 are the year, 3 and 4 the week (01 to 53), and the rest is a production number that can include a letter. CPSC’s 2018 notice, quoted above, names Whirlpool among the brands it covers: some Ultra-Low NOx gas heaters made from 2011 to 2016. American Water Heater, which built Whirlpool’s heaters, used the same code before the A.O. Smith purchase; its warranty example, 9843113460 (week 43 of 1998), is in the American table above.
A week number doesn’t give the day, so the checker shows the month the week falls in. For a Whirlpool heater, choose Whirlpool (water heater) in the checker above to get its date notes.
| Whirlpool serial | Year | Week | Built | Where the example comes from |
|---|---|---|---|---|
| 1104T403904 | 2011 | 4 | late January 2011 | Building Intelligence Center (Whirlpool) |
| 0128104380 | 2001 | 28 | July 2001 | Building Intelligence Center (Whirlpool) |
| 1115 to 1631 | 2011 to 2016 | week 15 of 2011 to week 31 of 2016 | April 2011 to August 2016 | CPSC 19-029 serial range |
Basis: official (CPSC recall 19-029; American Water Heater warranty, 2022); examples from Building Intelligence Center and CPSC 19-029’s serial range. InterNACHI’s dating chart gives the same rule for American and Whirlpool heaters.
No readable date? Enter the serial in Whirlpool’s warranty check; the result it returns includes a manufacturing date. For water heater service, Whirlpool lists 1-833-747-0686.
Kenmore water heaters
Sears sold Kenmore water heaters made by other companies. In the checker above, choose Kenmore (water heater) for these. Most model numbers start with 153 (some Kenmore Survivor models start with 449). The prefix doesn’t identify the maker: New York City equipment approvals list 153 models built by A.O. Smith (McBee, South Carolina, 2004) and by American Water Heater (Johnson City, Tennessee, 2008).
| Era | Maker (evidence) |
|---|---|
| 1961–1980 | State Industries made the Sears LP gas heaters in CPSC’s 1980 recall (“the Sears water heaters were manufactured by State Industries”) |
| About 2004 | A.O. Smith, McBee plant (NYC approval 22-05-E) |
| About 2008 | American Water Heater (NYC approval 87-88-E) |
| 2011–2016 | A.O. Smith group: Kenmore is on CPSC’s year + week recall list (19-029) |
State, A.O. Smith and American all belong to A.O. Smith today, so most Kenmore heaters use one of this page’s two codes:
- Four digits first (from about 2008): the year, then the week. Building Intelligence Center’s Kenmore page gives 1210A002243 (week 10 of 2012, early March) and S1318F000046 (week 18 of 2013, early May), both read in the year-and-week section. The S serial is the only documented example of a leading S, and we don’t know what the S means; skip it.
- Letter first, then two digits (before about 2008): the letter gives the month, from the letter table (A is January through M, skipping I), and the digits give the year. A03307353 is January 2003; J06A059461 is September 2006.
Basis: official. CPSC 19-029 backs the year + week reading, and the month letters come from the serial table in CPSC’s 2005 recall of A.O. Smith heaters, where J is September. The Kenmore examples are Building Intelligence Center’s. Letters gave way to year + week around 2008; we couldn’t find the exact month of the change.
Rheem-made Kenmore? Inspectapedia and Building Intelligence Center say some Kenmore heaters were made by Rheem, which reads the month then the year. We found no official record of this. If your plate names Rheem as the maker, use Rheem’s code.
A conflicting reading. Inspectapedia reads Kenmore serial 1112A011137 as year + month (December 2011). CPSC’s 2011–2016 recall reads Kenmore serials as year + week, which gives late March 2011.
Whirlpool and Kenmore recalls
Four recalls listed above also cover these brands. The Whirlpool, Kenmore and Sears details:
| Recall | Whirlpool, Kenmore or Sears detail | How to tell |
|---|---|---|
| CPSC 19-029 (Nov 2018) | Whirlpool and Kenmore Ultra-Low NOx 30-, 40- and 50-gallon gas heaters, sold mainly in California: fire hazard | Ultra-Low NOx models only, serials starting 1115 to 1631 (made April 8, 2011 to August 1, 2016). Recall lines: Whirlpool 866-854-2793, Kenmore 866-880-4661 |
| CPSC 05-274 (Sep 2005) | Whirlpool is one of the brands fitted with the recalled Robertshaw R110 gas valve (full entry in the American recalls table) | Valve production date codes 5-31 through 5-33; electric heaters aren’t included |
| CPSC 04-128 (Apr 2004) | Kenmore is one of the brands fitted with the recalled White-Rodgers LP and convertible gas control | Control models 37C55U 658, 37C57U 602, 37C72U 520, 546, 547, 548 or 676 (white label on the right side of the control), with a metal-stamped date code 0240 to 0329 below the label |
| CPSC 80-042 (1980) | LP gas heaters State made for Sears, sold as Economiser, Homart, Honor Bilt, Powermiser and Sears: the LP gas thermostat is an explosion hazard | Heaters sold 1961–1980 |
Basis: official (CPSC notices in the sources). Old recalls may have closed; check the notice for the exact models, and run the model through our recall check.
Whirlpool and Kenmore: age and limits
The lifespans in what the age means apply to these tanks too; if yours is past 10 years, the makers suggest planning a replacement before it fails.
Basis: official (manufacturer guidance listed in the sources).
- We couldn’t find exactly when Whirlpool-brand heaters stopped. The checker flags a Whirlpool reading after 2018, or before the 2000 license, as uncertain.
- We haven’t seen a Whirlpool water heater serial that starts with a month letter, or a documented code for the Whirlpool hybrid heat pump model. Use the printed date or Whirlpool’s lookup for those.
- Kenmore heaters made by different companies share the 153 prefix, so the serial’s layout, not the model number, tells you which code to use.
- The CPSC notices confirm the year + week code only for the recalled Ultra-Low NOx models; for other Whirlpool and Kenmore heaters it rests on American Water Heater’s warranty example and inspector references.
Checked against the sources below on 30 September 2026. The American section moved here from its own page on 25 October 2026, and the Whirlpool and Kenmore section on 1 November 2026, each with its sources.